AS-Interface emergency off button | VAA-2E-F85-V1

Article: VAA-2E-F85-V1
Name: AS-Interface emergency off button | VAA-2E-F85-V1
Manufacturer: Pepperl-Fuchs


Not available for purchase, If you need assistance please contact us sales@quad-industry.com
Îáîðóäîâàíèå ñíÿòî ñ ïðîèçâîäñòâà, äëÿ óòî÷íåíèÿ çàìåíû ñâÿæèòåñü ñ íàìè sales@quad-industry.com

  • Protection degree IP65 and IP69k
  • Outwit-proof according to ISO 13850/EN 418
  • 2-channel, compelled connected
  • TÜV-approval for system components is available

Datasheet as PDF in following languages:


Technical Data: VAA-2E-F85-V1

Product Description
AS-Interface emergency off button
General specifications
Slave typeStandard slave
Functional safety related parameters
MTTFd200 a
B10d1 E+5
Electrical specifications
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Rated operating current≤ 20 mA
Protection classIII
Input
Number/Type2 NC
Safety function by positive opening
in accordance with IEC/EN 60947-5-1
Reset by pulling
Supplyfrom AS-Interface
Programming instructions
ProfileS-7.B.E
IO code7
ID codeB
ID1 code0
ID2 codeE
Data bits (function via AS-Interface) input output
D0 dyn. safety code 1 -
D1 dyn. safety code 1 -
D2 dyn. safety code 2 -
D3 dyn. safety code 2 -
Parameter bits (programmable via AS-i)function
P0not used
P1not used
P2not used
P3not used
Ambient conditions
Ambient temperature-25 ... 55 °C (-13 ... 131 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Mechanical specifications
Protection degreeIP65 in accordance with EN 60529 and IP69k
ConnectionM12 round connector


Back to the section