Miniature Circuit Breaker - S200M - Number of Poles 4 - Tripping characteristic C - Rated Current 2.00 A | 2CDS273103R0024 | S203M-C2NA
|
Наименование: Miniature Circuit Breaker - S200M - Number of Poles 4 - Tripping characteristic C - Rated Current 2.00 A | 2CDS273103R0024 | S203M-C2NA
Производитель: ABB
Картинки описания: 2CDS273103R0024
|
|
General Information Extended Product Type: S203M-C2NA Product ID: 2CDS273103R0024 Catalog Description: Miniature Circuit Breaker - S200M - Number of Poles 4 - Tripping characteristic C Long Description: System pro M compact S200M miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 10 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200M comply with IEC/EN 60898-1 and IEC/EN 609 47-2, allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200M to save 50% space. Ordering Container Information Package Level 1 Gross Weight: Dimensions Technical Standards: IEC/EN 60898-1 IEC/EN 60947-2 Rated Operational Voltage (Ue): Rated Insulation Voltage (Ui): Phase to Ground 250 V AC Phase to Phase 500 V AC Operational Voltage: Maximum 440 V AC Maximum 125 V DC Minimum 12 V AC Minimum 12 V DC Rated Short-Circuit Capacity ( Icn ): Rated Ultimate Short-Circuit Breaking Capacity (Icu): Rated Service Short-Circuit Breaking Capacity (Ics): Rated Impulse Withstand Voltage (Uimp): 4 kV (6.2 kV @ sea level) (5.0 kV @ 2000 m) Housing Material: Insulation group I, RAL 7035 Actuator Type: Insulation group II, black, sealable Contact Position Indication: Remarks: IP40 in enclosure with cover Electrical Endurance (Nelec): Mechanical Endurance (Nendu): Screw Terminal Type: Failsafe Bi-directional Cylinder-lift Terminal Connecting Capacity: Busbar 10 / 10 mm? Rigid 0.75...25 mm? Stranded 0.75...25 mm? Flexible 0.75...16 mm? Flexible with Ferrule 0.75...16 mm? Recommended Screw Driver: Mounting on DIN Rail: TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 Technical UL/CSA Tightening Torques UL/CSA: Environmental Ambient Air Temperature: Operation -25 … +55 °C Storage -40 ... +70 °C Reference Temperature for Tripping Characteristics: Resistance to Shock acc. to IEC 60068-2-27: Resistance to Vibrations acc. to IEC 60068-2-6: 5g, 20 cycles at 5...150...5 Hz with load 0.8 In Environmental Conditions: 28 cycles with 55 °C / 90-96% and 25 °C / 95-100% RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment Certificates and Declarations (Document Number) Declaration of Conformity - CE: Environmental Information: Classifications ETIM 4.0: EC000042 - Miniature circuit breaker (MCB) ETIM 5.0: EC000042 - Miniature circuit breaker (MCB)
|
Назад в раздел
|