Miniature Circuit Breakers MCBs - S200U - Number of Poles 2 - Tripping characteristic K - Rated Current 0.50 A | 2CDS272417R0157 | S202U-K0,5
|
Наименование: Miniature Circuit Breakers MCBs - S200U - Number of Poles 2 - Tripping characteristic K - Rated Current 0.50 A | 2CDS272417R0157 | S202U-K0,5
Производитель: ABB
Картинки описания: 2CDS272417R0157
|
|
General Information Extended Product Type: S202U-K0,5 Product ID: 2CDS272417R0157 Catalog Description: Miniature Circuit Breakers MCBs - S200U - Number of Poles 2 - Tripping characteristic K Long Description: System pro M compact S200U miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (K,Z), configurations (1P,2P,3P,4P), breaking capacities (up to 10 kA) and rated currents (up to 63A). All MCBs of the product range S200U comply with IEC/EN 609 47-2, UL489 and CSA 22.2 No. 5, allowing the use for commercial and industrial applications. Spare Part Supplier Information - FIPSE Product Availability Class: From stock if available, otherwise see maximum delivery time Ordering Container Information Package Level 1 Gross Weight: Dimensions Technical Standards: IEC/EN 60947-2 UL 489 CSA 22.2 No. 5 Rated Operational Voltage (Ue): Rated Insulation Voltage (Ui): Phase to Ground 250 V AC Phase to Phase 500 V AC Operational Voltage: Maximum 440 V AC Minimum 12 V AC Rated Short-Circuit Capacity ( Icn ): Rated Ultimate Short-Circuit Breaking Capacity (Icu): Rated Service Short-Circuit Breaking Capacity (Ics): Rated Impulse Withstand Voltage (Uimp): 4 kV (6.2 kV @ sea level) (5.0 kV @ 2000 m) Housing Material: Insulation group I, RAL 7035 Actuator Type: Insulation group II, black, sealable Contact Position Indication: Remarks: IP40 in enclosure with cover Electrical Endurance (Nelec): Mechanical Endurance (Nendu): Screw Terminal Type: Failsafe Bi-directional Cylinder-lift Terminal Connecting Capacity: Busbar 10 / 10 mm? Rigid 0.75...25 mm? Stranded 0.75...25 mm? Flexible 0.75...16 mm? Flexible with Ferrule 0.75...16 mm? Recommended Screw Driver: Mounting on DIN Rail: TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 Technical UL/CSA Maximum Operating Voltage UL/CSA: Connecting Capacity UL/CSA: Busbar 18 - 8 AWG Conductor 18 - 4 AWG Tightening Torques UL/CSA: Short-Circuit Current Rating (SCCR): Environmental Ambient Air Temperature: Operation -25 … +55 °C Storage -40 ... +70 °C Reference Temperature for Tripping Characteristics: Resistance to Shock acc. to IEC 60068-2-27: Resistance to Vibrations acc. to IEC 60068-2-6: 5g, 20 cycles at 5...150...5 Hz with load 0.8 In Environmental Conditions: 28 cycles with 55 °C / 90-96% and 25 °C / 95-100% RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment Certificates and Declarations (Document Number) Declaration of Conformity - CE: Environmental Information: Classifications ETIM 4.0: EC000042 - Miniature circuit breaker (MCB) ETIM 5.0: EC000042 - Miniature circuit breaker (MCB)
|
Назад в раздел
|