| | SIRIUS SAFETY RELAY FOR SAFETY-ORIENTED STANDSTILL MONITORING, 400V AC, 45.0MM, SPRING-LOADED TERMINAL, FK INSTANT.: 3NO 1NC, FK DELAYED: 0, MK: 3, AUTO START, BASIC UNIT, MAX. ACHIEV. CAT. EN954-1: 4, MAX. ACHIEV. SIL TO IEC61508:3, |
| |
| General technical details: |
| Product brand name | | SIRIUS |
| product designation | | safety relays |
| Design of the product | | for safe stoppage monitoring |
| protection class IP / of the housing | | IP20 |
| Protection class IP / of the terminal | | IP20 |
| Protection against electrical shock | | finger-safe |
| Insulation voltage / rated value | V | 690 |
| Ambient temperature | | |
| | °C | -40… +75 |
| | °C | -25… +60 |
| Air pressure | | |
| | kPa | 90… 106 |
| Relative humidity | | |
| | % | 10… 95 |
| Installation altitude / at a height over sea level / maximum | m | 2,000 |
| Resistance against vibration / according to IEC 60068-2-6 | | 10 ... 55 Hz: 0.35 mm |
| Resistance against shock | | 8g / 10 ms |
| Impulse voltage resistance / rated value | V | 6,000 |
| EMC emitted interference | | IEC 61000-6-2, IEC 61000-6-3 |
| Item designation | | |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | KT |
- according to DIN EN 61346-2
| | F |
| Number of sensor inputs | | |
| | | 1 |
| Design of the cascading | | none |
| Type of the safety-related wiring / of the inputs | | measuring inputs |
| Product feature / transverse contact-secure | | No |
| safety Integrated Level / according to IEC 61508 | | SIL3 |
| SIL claim limit (for a subsystem) / according to EN 62061 | | 3 |
| Performance level (PL) / according to ISO 13849-1 | | e |
| Category / according to EN 954-1 | | 4 |
| Category / according to ISO 13849-1 | | 4 |
| Probability of dangerous failure per hour (PFHD) / with high demand rate / according to EN 62061 | 1/h | 0.15E-8 |
| T1 value / for proof test interval or service life / according to IEC 61508 | a | 20 |
| Number of outputs / as contact-affected switching element | | |
- as NC contact / for reporting function / instantaneous switching
| | 2 |
- as NO contact / safety-related / instantaneous switching
| | 4 |
- as NO contact / safety-related/ delayed switching
| | 0 |
| Number of outputs / as contact-less semiconductor switching element | | |
| | | |
| | | 0 |
| | | 0 |
| | | |
| | | 0 |
| | | 2 |
| Stop category / according to DIN EN 60204-1 | | 0 |
| |
| General technical details: | | |
| Design of the input | | |
- cascading-entrance/operation-even switching
| | No |
| | | Yes |
| | | No |
| Design of the electrical connection / jumper socket | | Yes |
| Operating cycles / maximum | 1/h | 1,200 |
| Switching capacity current / of semiconductor outputs | | |
- for signaling function / for DC-13 / at 24 V
| A | 0.1 |
| Switching capacity current / of the NO contacts of the relay outputs | | |
| | | |
| | A | 2 |
| | | |
| | A | 3 |
| | A | 3 |
| Switching capacity current / of the NC contacts of the relay outputs | | |
| | | |
| | A | 2 |
| | | |
| | A | 2 |
| | A | 2 |
| Thermal current / of the contact-affected switching element / maximum | A | 5 |
| Electrical operating cycles as operating time / typical | | 200,000 |
| Mechanical operating cycles as operating time / typical | | 50,000,000 |
| Design of the fuse link / for short-circuit protection of the NO contacts of the relay outputs / required | | quick: 5 A |
| |
| Control circuit: | | |
| Type of voltage / of the controlled supply voltage | | AC |
| Control supply voltage frequency | | |
| | Hz | 50 |
| | Hz | 60 |
| Control supply voltage / 1 / at 50 Hz / for AC / rated value | V | 400 |
| Control supply voltage / 1 / at 60 Hz / for AC / rated value | V | 400 |
| Working range factor supply voltage rated value / of the magnet coil | | |
| | | |
| | | 0.8… 1.1 |
| | | |
| | | 0.8… 1.1 |
| |
| |
| Installation/mounting/dimensions: | | |
| Built in orientation | | any |
| Type of mounting | | screw and snap-on mounting |
| Width | mm | 45 |
| Height | mm | 138.5 |
Depth
|