| SINVERT PVS2000 PV-INVERTER, 600SERIES, IEC 60HZ, 3P NOM. ACTIVE POWER (AC): 2000KVA GRID CONNECT. MV TRANS, MPP-RANGE: 450-750V, UMAX 820VDC, 12 DC-INPUTS, IP20, AIR COOLING, INVERTER UNIT AMOUNT: 4, OPTIONS AVAILABLE. FOR: 1000V-OPTION (UDCMAX 1000V), PV FIELD POSITIVE GROUNDING, PV FIELD MINUS GROUNDING , SYMMETRY MONITORING, CABINET HEATING, SINVERT PVS WARRANTY 5 YEARS, |
|
General technical data: |
Output class for PV inverters | | 2000 |
Efficiency | | |
| % | 98.4 |
| % | 98.3 |
| % | 98.3 |
Design of PV inverter unit | | master-slave combination |
Number of PV inverter sub-units | | 4 |
Type of installation | | indoor installation |
Protection class IP | | IP20 |
Operating resource protection class | | I |
Design of the interface / for communication | | Ethernet |
A-rated sound power level / maximum | dB | 80 |
Design of the display | | LCD-TFT |
National language / at the indicator of the display / selectable | | English, German |
Connection method for PV inverters | | without transformer |
|
Output (AC side): | | |
Phase number | | 3 |
Output voltage / on the AC side / for infeed operation | | |
| V | 288 |
| V | 244.8 |
| V | 316.8 |
Power factor / at nominal value of active power supplied / nominal value | | 1 |
Power factor inductive | | 0.8 |
Power factor capacitive | | 0.8 |
Active power supplied / on the AC side | | |
- in permanent operation / nominal value
| W | 2,000,000 |
| W | 2,000,000 |
Current supplied / on the AC side / maximum | A | 4,008 |
Line frequency / suitable for infeed operation | | |
| Hz | 60 |
| Hz | 58.8 |
| Hz | 61.2 |
Relative residual ripple / of AC current / at nominal value of the AC active power / on unloaded line / maximum | % | 2 |
Grounding concept / on the AC side | | IT |
Design of the overvoltage protection / on the AC side | | type 1/2 |
|
Input (DC side): | | |
MPP voltage | V | 450… 750 |
Consumed active power / on the DC side / nominal value | W | 2,052,000 |
Input voltage / on the DC side | | |
- for the start of the infeed operation
| V | 600 |
- for possible infeed operation
| V | 450… 750 |
| V | 465 |
| V | 820 |
Number of inputs / on the DC side | | 12 |
Input current / per DC input / maximum | A | 368 |
Total power used / on the DC side / maximum | A | 4,412 |
Overcurrent strength / per DC input / nominal value | A | 368 |
Product component / on the DC side / overvoltage protection per DC input | | Yes |
Design of the overvoltage protection / on the DC side | | type 2 |
|
External auxiliary voltage supply: | | |
Auxiliary voltage / nominal value | V | 400 |
Auxiliary voltage frequency / nominal value | Hz | 60 |
effective power consumed / from external auxiliary supply | | |
- for infeed mode / without cabinet heating / maximum
| W | 14,000 |
- for infeed mode / with cabinet heating / maximum
| W | 15,000 |
- in night-time operating mode
| | |
- without cabinet heating / maximum
| W | 1,400 |
- with cabinet heating / maximum
| W | 2,400 |
Grounding concept / for auxiliary power supply external | | TN-S |
|
Ambient conditions: | | |
Installation altitude | | |
| m | 0… 1,000 |
| m | 2,000 |
Incoming air temperature / at nominal value of active power supplied / maximum | °C | 40 |
Ambient temperature | | |
| °C | 0… 50 |
| °C | -25… +70 |
| °C | -25… +70 |
Relative humidity | | |
| % | 0… 95 |
| % | 0… 95 |
| % | 0… 95 |
Climatic class | | 3K3 |
Type of cooling | | forced-air cooling via fan |
Cooling air flow | m³/h | 26,000 |
Nature of the ventilation | | air intake cabinet front/air outlet cabinet top |
|
Mechanical data: | | |
Width / of PV inverter subunits | mm | 2,700 |
Height / of PV inverter subunits | mm | 2,100 |
Depth / of PV inverter subunits | mm | 730 |