Product-type designation | SCALANCE X320-3LD FE |
| SCALANCE X320-3LDFE MANAGED IE SWITCH, 20 X 10/100 MBIT/S RJ45 PORTS, 1 X 100MBIT/S SC PORT MM 2 X 100MBIT/S SC PORT SM LED-DIAGNOSTICS, FAULT SIGNAL CONTACT WITH SELECT/ SET BUTTON, PROFINET-IO DEVICE, NETWORK- MANAGEMENT, INTEGRATED REDUNDANCY MANAGER OFFICE FEATURES (RSTP, VLAN, IGMP,..) C-PLUG IN THE SCOPE OF SUPPLY |
Transmission rate | |
Transfer rate / 1 | 10 Mbit/s |
Transfer rate / 2 | 100 Mbit/s |
Interfaces | |
Number of electrical/optical connections / for network components or terminal equipment / maximum | 23 |
Number of electrical connections | |
- for network components and terminal equipment
| 20 |
| 1 |
| 1 |
- for redundant power supply
| 2 |
Design of electrical connection | |
- for network components and terminal equipment
| RJ45 port |
| 2-pole terminal block |
| 4-pole terminal block |
Number of optical interfaces / for optical waveguide | |
| 3 |
Design of optical interface / for optical waveguide | |
| SC port (1 x multimode up to 5 km, 2 x singlemode up to 26 km) |
Connectable optical power relative to 1 mW | |
- of the transmitter output
| -15… -8 dB |
- of the receiver input / maximum
| -3 dB |
Optical sensitivity relative to 1 mW / of the receiver input / minimum | -34 dB |
Attenuation / of fiber-optic cable transmission link / minimum necessary | 0 dB |
Range / at the optical interface / depending on the optical fiber used | 0… 26 km |
design of the removable storage / C-PLUG | Yes |
Inputs/outputs | |
Operating voltage / of signaling contacts / at DC / rated value | 24 V |
Operating current / of signaling contacts / at DC / maximum | 0.1 A |
Supply voltage, current consumption, power loss | |
Type of supply voltage / redundant power supply unit | No |
Type of voltage / of supply voltage | DC |
Supply voltage | |
| 24 V |
| 18… 32 V |
Product component / fusing at power supply input | Yes |
Consumed current / maximum | 0.5 A |
Power loss | |
| 12 W |
Permitted ambient conditions | |
Ambient temperature | |
| -40… +60 °C |
| -40… +70 °C |
| -40… +70 °C |
Relative humidity | |
- at 25 °C / without condensation / during operating / maximum
| 95 % |
Protection class IP | IP30 |
Design, dimensions and weight | |
Design | compact |
Width | 180 mm |
Height | 125 mm |
Depth | 123 mm |
Net weight | 1.65 kg |
Type of mounting | |
| No |
| Yes |
| Yes |
| Yes |
Type of mounting | When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted |
Product properties, functions, components / general | |
Cascading in the case of a redundant ring / at reconfiguration time of <\~0.3\~s | 50 |
Cascading in cases of star structuring | Any (depending only on signal propagation time) |
Product function | |
| Yes |
| Yes |
| Yes |
| Yes |
- Configuration with STEP 7
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
Protocol / is supported | |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes
|