Product type designation | SCALANCE W786-2HPW |
| IWLAN ACCESS POINT SCALANCE W786-2HPW FOR OPERATION WITH HIPATH WLAN CONTROLLER NOTE NATIONAL APPROVALS, 48VDC, IP65(-40-+70 DGR C) 4XEXT. ANTENNENA CONNECTIONS 2 RADIO INTERFACES, FO (GLASS-FOC,MULTIMODE) SOCKET SCOPE OF SUPPLY: MOUNTING MATERIAL, MANUAL GERMAN / ENGLISH |
Transmission rate | |
Transmission rate | |
| 54 Mbit/s |
| 10 Mbit/s… 100 Mbit/s |
| Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Interfaces | |
Number of electrical connections | |
| 1 |
- for redundant power supply
| 1 |
Design of electrical connection | |
| 2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 24 V DC or 3-pole 110 to 230 V AC) |
Number of optical interfaces / for optical waveguide / at 100 Mbit/s | 1 |
Design of optical interface / for optical waveguide / at 100 Mbit/s | Duplex multimode FOC (ST) |
design of the removable storage / C-PLUG | Yes |
Interfaces / wireless | |
Number of radio cards / permanently installed | 2 |
Number of electrical connections / for external antenna(s) | 4 |
Design of the electrical connection / for external antenna(s) | R-SMA female (socket) |
Supply voltage, current consumption, power loss | |
Type of voltage / of supply voltage | DC |
Supply voltage | |
- from Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af
| 48 V |
Current consumed | |
- at 24 V / with DC / typical
| 0.4 A |
- with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af / typical
| 0.2 A |
Active power loss | |
- at 24V / for DC / typical
| 9.5 W |
- with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af / typical
| 9.5 W |
Permitted ambient conditions | |
Ambient temperature | |
| -40 °C… 70 °C |
| -40 °C… 85 °C |
| -40 °C… 85 °C |
Relative humidity / at 25 °C / without condensation / during operating / maximum | 100 % |
Protection class IP | IP65 |
Ambient condition / for (standard) operation mode | When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible |
Design, dimensions and weight | |
Width / of enclosure / without antenna | 251 mm |
Height / of enclosure / without antenna | 251 mm |
Depth / of enclosure / without antenna | 72 mm |
Net weight | 2.24 kg |
Type of mounting / wall mounting | Yes |
Type of mounting | For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required |
Wireless frequencies | |
Radio frequency | |
- for WLAN in 2.4 GHz frequency band
| 2.41 GHz… 2.48 GHz |
- for WLAN in 5 GHz frequency band
| 4.9 GHz… 5.8 GHz |
Product functions / management, configuration | |
Product function | |
- operation with IWLAN controller
| Yes |
- operation with Enterasys WLAN controller
| Yes |
Standards, specifications, approvals | |
Standard | |
| FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
| EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
- for safety / of CSA and UL
| UL 60950-1 CSA C22.2 No. 60950-1 |
- for hazardous area / of CSA and UL
| UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 |
Verification of suitability | |
| Yes |
- EC declaration of conformity
| Yes |
| Yes |
| No |
- Railway application in accordance with EN 50155
| No |
| Yes |
| Yes |
| Yes |
- Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af
| Yes |
Standard for wireless communication | |
| Yes |
| Yes |
| Yes |
| Yes |
| No |
Marine classification association | |
- American Bureau of Shipping Europe Ltd. (ABS)
| Yes |
| Yes |
| No |
| Yes |
- Lloyds Register of Shipping (LRS)
| Yes |
| Yes |
- Polski Rejestr Statkow (PRS)
| No |
Accessories | |
Accessories<
|