120 Vac dual direct ignition gas valve || VR4305M4540/B

Артикул: VR4305M4540/B
Наименование: 120 Vac dual direct ignition gas valve
Производитель: Honeywell


Overview

Combination gas control for use with hot surface/direct spark systems in 120 Vac, gas-fired appliances, with capacities from 30 to 415 cfh.

Features

  • Controls include manual valve, two automatic operators and pressure regulator.
  • Compact size.
  • Provides two automatic valves.
  • Solenoid operated first automatic valve opens on thermostat call for heat, closes when call for heat ends.
  • Diaphragm-operated second automatic valve opens under control of regulator, closes if gas or power supply is interrupted.
  • Meets codes requiring dual safety shut-off.
  • Natural to LP and LP to Natural conversion kits available for standard and slow opening gas valves.
  • Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure.
  • ON/OFF lighting sequence.

Product Specifications

Application
Single Stage
Includes
393691 Natural to LP conversion kit, 390427 pipe bushing.
Mounting
0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Frequency
60 Hz
Approvals, Underwriters Laboratories Inc.
UL Component Recognized.
Electrical Connections
1/4 in. male quick-connects, 24 in. (610 mm) leadwires.
Voltage
120 Vac
Operating Temperature Range (F)
-40 F to +175 F
Operating Temperature Range (C)
-40 C to +79 C
Approvals, Canadian Gas Association
CGA Design Certificate: L2025006
Body Pattern
Straight-through
Opening Characteristics
Standard Opening
Pressure Ratings (psi)
1/2 psi
Pressure Ratings (kPa)
3.5 kPa
Inlet/Outlet Size (in.)
3/4 in. x 3/4 in.
Pilot Gas Outlet
none
Pressure Tapping
Inlet and outlet pressure taps included. Taps accessible from top of gas control. Taps are 1/8 in. NPT with plug containing recess for 3/16 in. Allen wrench.
Approvals, American Gas Association
AGA Design Certificate: L2025006
Type of Fuel
Natural
Capacity (kBtuh)
At 1 in. wc p.d.-- 300,000 BTUh: 30,000 BTUh minimum
Pressure Regulator Setpoint (in. wc)
3.5 in. wc
Pressure Regulator Setpoint (kPa)
0.87 kPa
Ignition Type
Direct Ignition
Anticipator Setting
0.13 A

 



Назад в раздел