Model 123 Load Cell:, 10000 Kg, -20 °C to 55 °C [-5 °F to 130 °F] temperature compensation, non-amplified (mV/V), PVC cable, 1,5 m [5 ft] cable length, radial electrical exit orientation || 060-K626-08

Àðòèêóë: 060-K626-08
Íàèìåíîâàíèå: Model 123 Load Cell:, 10000 Kg, -20 °C to 55 °C [-5 °F to 130 °F] temperature compensation, non-amplified (mV/V), PVC cable, 1,5 m [5 ft] cable length, radial electrical exit orientation || 060-K626-08
Ïðîèçâîäèòåëü: Honeywell





Description
The Model 123 load cell combines both a compact and high precision form to offer a superior tension and compression force transducer. The one-piece, S-shaped design achieves a maximum non-linearity of 0.03% full scale for load ranges from 1,000 kg to 20,000 kg.

Features
  • Economical and popular design for a variety of tension force measurements
  • Load ranges from 20 kg to 1,000 kg, up to 1,000 kg to 20,000 kg
  • ±0.02 % or ±0.03 % accuracies, full scale
  • One-piece, nickel-plated, alloy steel construction
  • Compact size
  • Integral cable

Potential Applications
  • Torque
  • Bending movements
  • Side loads
  • General applications

Product Specifications
Order Code BL810LW,1AH,2U,6F,15C
Range 10,000 Kg
Accuracy ±0.03 % full scale
Output 2 mV/V (nominal)
Operation Compression/Tension
Temperature (Operating) -30 °C to 70 °C [-22 °F to 158 °F]
Temperature (Compensated) -20 °C to 55 °C [-4 °F to 131 °F]
Temperature Effect (Zero) ±0.03 % full scale/10 °C
Temperature Effect (Span) ±0.03 % full scale/10 °C
Electrical Termination (std.) 6 m [19.69 ft] of 5 mm [0.2 in] diameter cable
Mating Connector None required
Case Material Nickel-plated Alloy Steel
Series Name Model 123


Íàçàä â ðàçäåë