TruStability® TSC Series, Compensated/Unamplified, analog, DIP, LN: single axial barbless port, gage, 0 psi to 100 psi || TSCDLNN100PGUCV

Àðòèêóë: TSCDLNN100PGUCV
Íàèìåíîâàíèå: TruStability® TSC Series, Compensated/Unamplified, analog, DIP, LN: single axial barbless port, gage, 0 psi to 100 psi || TSCDLNN100PGUCV
Ïðîèçâîäèòåëü: Honeywell





Description

Honeywell’s TruStability® TSC Series are piezoresistive silicon pressure sensors offering a ratiometric analog output for reading pressure over the specified full scale pressure span and temperature range:

  • Temperature compensated and unamplified.
  • Compensation makes it easier to integrate the sensor into a system by eliminating the need to calibrate the system over temperature and also offers reduced part-to-part variation.
  • Compensated temperature range is 0 °C to 85 °C [-32 °F to 185 °F].
  • Operating temperature range is -40 °C to 85 °C [-40 °F to 185 °F].
  • Measures differential or gage pressures.
  • The absolute versions have an internal vacuum reference and an output value proportional to absolute pressure. Differential versions allow measurement of pressure between two pressure ports. Gage versions are referenced to atmospheric pressure and provide an output proportional to pressure variations from atmosphere.

    The TSC Series sensors is intended for use with non-corrosive, non-ionic gases, such as air. Port 1 can also be used for non-corrosive, non-ionic liquids on sensors rated above 60 mbar | 6 kPa | 1 psi.

    The TSC Series offers numerous package styles and mounting options, making it easier for device manufacturers to integrate the product into their applications. These sensors offer infinite resolution on the pressure signal. Frequency response is also typically limited only by the end user’s system. All products are designed and manufactured according to ISO 9001.

    Features

    • Industry-leading long-term stability: Even after long-term use and thermal extremes, these sensors perform substantially better relative to stability than any other pressure sensor available in the industry today:
      • Minimizes system calibration needs and maximizes system performance.
      • Helps support system uptime by eliminating the need to service or replace the sensor during its application life.
    • Industry-leading accuracy: Extremely tight accuracy down to ±0.15 %FSS BFSL:
      • Reduces software needed to correct system inaccuracies, minimizing system design time.
      • Supports system accuracy and warranty requirements.
    • Industry-leading flexibility:
      • Modular, flexible design with numerous package styles, pressure ports, and options simplifies integration into the device manufacturer’s application.
      • Single side wet media option allows the end customer to use one port of the sensor with condensing humidity or directly with non-corrosive liquid media.
    • Insensitive to mounting orientation: Allows flexibility of use within the application.
    • Small size: Miniature 10 mm x 10 mm [0.39 in x 0.39 in] package is very small when compared to most board mount pressure sensors:
      • Occupies less area on the PCB.
      • Typically allows for easy placement on crowded PCBs or in small devices.
    • Repeatability: Provides excellent repeatability, high accuracy and reliability under many demanding conditions.
    • Supports lean manufacturing:
      • J-STD-020-D MSL 1 unlimited shelf life after packaging is opened.
      • System can be calibrated within one hour after reflow solder.
      • Compatible with modern lead-free and no-clean solder processes.
    • Extremely low power consumption:
      • Operating supply voltage as low as 1.5 Vdc.
      • Reduces power consumption, provides extended battery life, and promotes energy efficiency.

    Potential Applications
    Medical
    • Nebulizers
    • Spirometers
    • Patient monitoring equipment
    • Therapeutic hospital beds
    • Hospital gas supply
    • Oxygen concentrators
    • Blood analysis
    • Gas chromatography
    • Analytical instruments
    Industrial
    • Valves
    • Pumps
    • Actuators
    • HVAC transmitters
    • Automated pneumatic assembly equipment
    • Pneumatic operator control systems
    • Industrial gas supply
    • Barometry
    • Gas chromatography
    • Analytical instrument sampling systems

    Product Specifications
    Measurement Type Gage
    Output Analog
    Signal Conditioning Unamplified
    Pressure Range 0 psi to 100 psi
    Overpressure 245 psi
    Supply Voltage 5 Vdc, typ.
    Supply Current 0.6 mA typ.
    Temperature Compensation Yes
    Output Calibration Yes
    Port Style LN: single axial barbless port
    Package Type DIP
    Accuracy (Best Fit Straight Line) ±0.15 %FSS
    Shock MIL-STD-202F, Method 213B, Condition F (100 g, 6 ms duration)
    Vibration MIL-STD-202F, Method 214A, Condition 1E (15 g, 10 Hz to 2 kHz)
    Operating Temperature -40 °C to 85 °C [-40 °F to 185 °F]
    Compensated Temperature Range 0 °C to 85 °C [32 °F to 185 °F]
    Storage Temperature -40 °C to 85 °C [-40 °F to 185 °F]
    Media Compatibility Non-corrosive, non-ionic gases, port 1 can also be used with non-corrosive, non-ionic liquids on sensors rated above 60 mbar | 6 kPa |1 psi.
    UNSPSC Code 41111927
    UNSPSC Commodity 41111927 Pressure Sensors
    Comment No special options
    Availability Global
    Series Name TruStability® TSC


    Íàçàä â ðàçäåë