BCL 358i OM 100 - Stationary barcode reader

Àðòèêóë: 50120754
Íàèìåíîâàíèå: BCL 358i OM 100 - Stationary barcode reader
Ïðîèçâîäèòåëü: Leuze electronic


Part description BCL 358i OM 100 - Stationary barcode reader
Part no. 50120754



  • Technical features

    • Basic data
      • SeriesBCL 300i
    • Read data
      • Code types, readableEAN 8/13, Code 93, Code 39, Code 128, UPC, GS1 Databar Expanded, GS1 Databar Limited, GS1 Databar Omnidirectional, Codabar, 2/5 Interleaved
      • Scanning rate, typical1.000 scans/s
    • Optics
      • Reading distance40 ... 300 mm
      • Light sourcelaser, Red
      • Laser light wavelength655 nm
      • Laser safety class2, EN 60825
      • Reading methodOscillating-mirror scanner
      • Beam deflectionVia rotating polygon wheel + stepping motor with mirror
      • Light beam exitZero position at side at angle less than 90°
    • Electrical equipment
      • Performance data
        • Supply voltage18 ... 30 V, DC
        • Power consumption, max.9 V·A
      • Inputs / outputs
        • Number of inputs/outputs selectable2 Piece(s)
    • Interface
      • TypeEtherNet IP
      • EtherNet IP
        • Switch functionalityintegrated
    • Service interface
      • TypeUSB
      • USB
        • FunctionConfiguration via software, Service
    • Connection
      • Number of connections1 Piece(s)
      • Connection 1
        • Type of connectionPlug connector
        • FunctionData interface, PWR / SW IN/OUT, BUS IN, Service interface, Connection to device
        • No. of pins32 Piece(s)
        • ModelMale
    • Mechanical data
      • DesignCube
      • Dimension125 mm x 58 mm x 110 mm
      • Housing materialMetal, Diecast aluminum
      • Lens cover materialGlass
      • Net weight580 g
      • Housing colorRed, Black
      • Type of fasteningFastening on back, Dovetail grooves
    • Operation and display
      • Type of displayLED
      • Number of LEDs2 Piece(s)
      • Type of configurationVia web browser
    • Environmental data
      • Ambient temperature, operation0 ... 40 °C
      • Ambient temperature, storage-20 ... 70 °C
      • Relative humidity (non-condensing)0 ... 90 %
    • Certifications
      • Protection classIP 65
      • Safety classIII
      • CertificationsCDRH, c UL US, CE
      • Test procedure for EMC in accordance with standardEN 55022, EN 61000-4-2, 3, -4, -6
      • Test procedure for shock in accordance with standardIEC 60068-2-27, test Ea
      • Test procedure for continuous shock in accordance with standardIEC 60068-2-29, test Eb
      • Test procedure for vibration in accordance with standardIEC 60068-2-6, test FC
    • Functions
      • FunctionsAutoControl, AutoReflAct, Code fragment technology, Alignment mode, LED indicators, Reference code comparison
  • Downloads

  • Part data of: 2013-11-24 21:03:00



    Íàçàä â ðàçäåë