SLSER 46B/66 - Single beam safety device receiver

Àðòèêóë: 50108541
Íàèìåíîâàíèå: SLSER 46B/66 - Single beam safety device receiver
Ïðîèçâîäèòåëü: Leuze electronic


Part description SLSER 46B/66 - Single beam safety device receiver
Part no. 50108541



  • Technical features

    • Basic data
      • Series46
      • Operating principleOne-way principle
      • Device typeReceiver
    • Characteristic parameters
      • Model2, IEC/EN 61496
      • MTTFd407 years, EN ISO 13849-1
      • Service life20 years, EN ISO 13849-1
      • Category2, EN ISO 13849
    • Timing
      • Switching frequency100 Hz
      • Response time5 ms
    • Electrical equipment
      • Protective circuitPolarity reversal protection, Short circuit protected
      • Performance data
        • Supply voltage10 ... 30 V, DC
      • Outputs
        • Number of digital switching outputs2 Piece(s)
        • Switching output 1
          • Switching elementTransistor, Push-pull
          • Switching principleLight switching (PNP)/dark switching (NPN)
        • Switching output 2
          • Switching elementTransistor, Push-pull
          • Switching principleDark switching (PNP)/light switching (NPN)
    • Connection
      • Number of connections1 Piece(s)
      • Connection 1
        • Type of connectionCable
        • FunctionVoltage supply, Signal IN, Signal OUT
        • Cable length2.000 mm
        • Sheathing materialPUR
        • Number of conductors4 Piece(s)
    • Mechanical data
      • DesignCube
      • Dimension18.5 mm x 76.9 mm x 43.4 mm
      • Housing materialplastic, PC-ABS
      • Lens cover materialplastic
      • Net weight100 g
      • Housing colorRed
      • Type of fasteningThrough-hole mounting
    • Operation and display
      • Type of displayLED
      • Number of LEDs2 Piece(s)
    • Environmental data
      • Ambient temperature, operation-30 ... 55 °C
      • Ambient temperature, storage-30 ... 60 °C
    • Certifications
      • Protection classIP 67, IP 69K
      • Safety classII
      • CertificationsCE, c UL US, TÃœV Süd
      • Standards appliedIEC 60947-5-2
  • Downloads

  • Part data of: 2013-11-24 21:03:00



    Íàçàä â ðàçäåë