Product Description |
Safety Monitor, 1 decentralized output circuit |
General specifications |
AS-Interface specification | V3.0 |
Switch-on delay | < 10 s |
Indicators/operating means |
LED AS-i 1 | from: no power supply green, continuous illuminated: AS-Interface power supply available |
LED AS-i 2 | from: normal operation red, continuous illuminated: communication error |
LED green | Off: contacts of the safety output (OSSD) open constantly lit: contacts of the safety output (OSSD) closed flashing: delay time running for Stop Category 1 |
LED yellow | off: - constantly lit: startup/restart lock active flashing: external test required |
LED red | Off: contacts of the safety output (OSSD) closed constantly lit: contacts of the safety output (OSSD) open flashing: error |
Electrical specifications |
Rated operating voltage | 24 V DC ± 15 % Residual ripple ≤ 15 % 18.5 ... 31.6 V from AS-Interface |
Rated operating current | ≤ 200 mA ≤ 45 mA from AS-Interface |
Surge protection | overvoltage category III for rated operating voltage 300 V DC acc. to VDE 0110 Part 1 |
Interface |
Interface type | RS 232, serial |
Transfer rate | 9600 baud, no parity, 1 start bit, 1 stop bit, 8 data bits |
Input |
Number/Type | 2 opto-coupling inputs (high-active) "Start" and "protection control (EDM)", input currents about 10 mA at 24 V DC |
Output |
Safety output | 2 potential-free NO contacts, max. contact loading: 1 A DC-13 at 24 V DC, 3 A AC-15 at 230 V AC |
Output type | Signal output: PNP transistor output, 200 mA, short-circuit and reverse-polarity-proof |
Response delay | < 50 ms |
Compliance with standards and directives |
Directive conformity | |
| Machinery Directive 2006/42/EC | EN 954-1:1996, EN 61496:2005, EN 60204-1:2006 |
| Low Voltage Directive 2006/95/EC | EN 60947-5-1:2005 |
| EMC Directive 2004/108/EC | EN 61000-6-2:2006, EN 61000-6-4:2007 |
Standard conformity | |
| AS-Interface | EN 50295:1999 |
| Functional safety | ISO 13849-1:2008 (up to category 4/PL e), IEC 61508:2000/IEC 62061:2005 (up to SIL3) |
| Electrical safety | EN 50178:1998 |
Ambient conditions |
Ambient temperature | -20 ... 60 В°C (-4 ... 140 В°F) |
Storage temperature | -30 ... 70 В°C (-22 ... 158 В°F) |
Mechanical specifications |
Protection degree | IP20 (only for use in electrical operating rooms / switch cabinet suitable with minimum protection type IP54) |
Connection | screw terminals |
Material | |
| Housing | Polyamide PA 66 , black |
Mass | 450 g |
Mounting | DIN rail mounting |