Not available for purchase, If you need assistance please contact us sales@quad-industry.com Оборудование снято с производства, для уточнения замены свяжитесь с нами sales@quad-industry.com
Analog output 4 mA ... 20 mA
5000 mm measurement range
Switch output programmable
Pre-fault indication and output
Protection degree IP64
Terminal compartment
Application specific devices available on request
Technical Data: OCD5000-F5-IE2
General specifications
Reference target
Grey card 18 % (grey) ... 90 % (white) reflection, 200 mm x 200 mm
Light type
880 nm IR light
Upper limit of the sensing range
5000 mm
Ambient light limit
≤ 13000 Lux sun light ≤ 10000 Lux halogen light
Indicators/operating means
LED yellow
switching state
Electrical specifications
Rated operating voltage
13 ... 30 V DC , ripple 10 %SS
No-load supply current
≤ 150 mA at UB = 10 ≤ 65 mA at UB = 30 V
Time delay before availability
200 ms
Output
Output type
1 analog output 4 ... 20 mA 1 switch output E2, PNP, NO 1 Pre-fault output PNP, NO
Rated operating current
switch output E2: 100 mA Output of the pre-fault indication 10 mA each short/overload protected