Evaluation unit | SLVA-8K 115VAC

Артикул: SLVA-8K 115VAC
Наименование: Evaluation unit | SLVA-8K 115VAC
Производитель: Pepperl-Fuchs



  • Self-monitoring (type 4 according to IEC/EN 61496-1)
  • Evaluation device for safety thru-beam sensors SLA and for safety light grids SLP
  • Operating mode can be selected by means of DIP switches
  • Start/Restart disable
  • Relay monitor
  • Sequential and parallel muting in various operating modes
  • Double muting
  • Emergency muting (override) for the correction of the material jam
  • Pre-fault indication
  • Clearly visible LED functional display
  • 7-segment diagnostic display
  • Safety outputs OSSD, external status displays OSSD

Datasheet as PDF in following languages:


Technical Data: SLVA-8K 115VAC

General specifications
Safety type according to IEC/EN 614964
MarkingCE
Operating modeStart/restart disable, relay monitor, muting operating modes
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd1.97 E-9
Indicators/operating means
Diagnostics display7-segment display
Function displayLED red: OSSD off
LED green: OSSD on
LED yellow 8x: indicator lamp channel 1 ... 8
LED yellow 2x: Type of muting sensor
LED yellow: Muting operation
Pre-fault indicationLED yellow flashing: Indicator lamp channel 1 ... 8
Electrical specifications
Operating voltage115 V\AC ± 10 %
Input
Function inputRelay monitor, start release, muting enable, emergency muting, max. 4 muting sensors
Output
Safety output2 relay outputs, force guided alternating contact
Signal outputRelay contacts for the switching state message of the OSSDs
Mechanical specifications
Protection degreeIP20
ConnectionConnection terminals, max. conductor cross-sectional area 1.5 mm2


Назад в раздел