Product Description |
Industrial monitor designed for continuous use in harsh environments |
General specifications |
Distance | Transmitter "K3": 300 m (1000 ft) Transmitter "K4": 120 m (400 ft) Transmitter "K5": 200 m (650 ft), 62.5 µ multimode; 400 m (1300 ft), 50.0 µ multimode |
Supply |
Connection | Monitor: power, CAT5, fiber (LC) |
Power consumption | Main unit: 20-30 VDC, 4.0 A max Transmitter "K3": PS2 power Transmitter "K4": 5 VDC @ 10 W, max Transmitter "K5": 5 VDC @ 10 W, max |
Indicators/operating means |
Indicators | Transmitter "K3": video check LED Transmitter "K4": video check LED; front panel - power Transmitter "K5": video check LED; front panel - power |
Display | |
| Screen diagonal | 19.0" (48.3 cm) |
| Response time | 15 ms |
| Resolution | 1280 x 1024 |
| Color depth | 24 bit (16.7 M) color |
| Contrast | 900:1 |
| Brightness | Standard: 300 nit Zone 2: 500 nit |
| Reading angle | 160В° in all directions |
| Life span | Back lamp life: 50,000 hrs typical half life |
Input devices | Transmitter "K3": VGA - HD15M/F; 2 x PS2 (keyboard & mouse); 1 x RS232 (touchscreen); 1 x RJ45 (CAT5e/6) Transmitter "K4": 29-pin DVI-D; 2 x USB Type A (keyboard, mouse/touchscreen); 1 x RS232 (touchscreen); 1 x RJ45 (CAT5e/6) Transmitter "K5": 29-pin DVI-D; 2 x USB Type A (keyboard, mouse/touchscreen); 1 x RS232 (touchscreen); fiber optic (multimode) LC connectors |
| Touchscreen | 5-wire resistive 5-wire hardened resistive |
Serial data |
Baud rate | 19.2 KBd max |
Flow control | RTS, CTS, DTR, DSR |
Directive conformity |
Electromagnetic compatibility | |
| Directive 89/336/EEC | EN55022A, EN61000-6-2, EN61000-3-2, EN61000-3-3 (main unit) EN55022, EN55024, IEC61000-4-2, IEC61000-4-3, IEC61000-4.4, IEC61000-4-5, EN61000-3-2, EN61000-3-3 (KVM transmitters) |
Low voltage | |
| Directive 73/23/EEC | EN60950 (KVM transmitters) |
Ambient conditions |
Operating temperature | -20 ... 50 В°C (-4 ... 122 В°F) |
Storage temperature | -20 ... 60 В°C (-4 ... 140 В°F) |
Relative humidity | 0 ... 90% (noncondensing) |
Mechanical specifications |
Protection degree | Type 4X ( stainless steel ) Type 4 ( painted steel ) IP66 |
Material | Bezel: black painted steel or 316L satinless steel |
Installation | panel mount panel cutout: 455 x 386 mm (17.9 x 15.2 inches) |
Mass | Main unit: 11.3 kg (25 lb) Transmitter "K3": 1.3 kg (2.9 lbs) Transmitter "K4": 0.3 kg (0.7 lbs) Transmitter "K5": 0.3 kg (0.7 lbs) |
Dimensions | Main unit: 483 x 411 x 92 mm (19 x 16.2 x 3.6 inches) Transmitter "K3": 198 x 99 x 36 mm (7.8 x 3.9 x 1.4 inches) Transmitter "K4": 104 x 135 x 36 mm (4.1 x 5.3 x 1.4 inches) Transmitter "K5": 104 x 135 x 36 mm (4.1 x 5.3 x 1.4 inches) |
Data for application in connection with Ex-areas |
EC-Type Examination Certificate | |
| Group, category, type of protection | II 3G Ex nA nC IIC T4 Gc II 3G Ex nA IIC T4 Gc |
Directive conformity | |
| Directive 94/9/EC | EN 60079-15:2010 , EN 60079-0: 2009 IECEx 60079-15 (4th addition) , IECEx 60079-0 (5th addition) |
International approvals |
UL approval | cULus : Class I/Div 2, A - D; Class II/Div 2, F & G; T4 |
IECEx approval | II 3G Ex nA nC IIC T4 Gc II 3G Ex nA IIC T4 Gc |