HART Output Isolator with Shutdown Input | FB4305C

Артикул: FB4305C
Наименование: HART Output Isolator with Shutdown Input | FB4305C
Производитель: Pepperl-Fuchs


Not available for purchase, If you need assistance please contact us sales@quad-industry.com
Оборудование снято с производства, для уточнения замены свяжитесь с нами sales@quad-industry.com

  • 4-channel
  • Outputs wired to Ex e terminals
  • Installation in suitable enclosures in Zone 1 or Zone 21
  • Analog output module for 0/4 mA ... 20 mA
  • HART communication via field bus or service bus
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD)
  • Output with watchdog
  • Permanently self-monitoring
  • Up to SIL2 acc. to IEC 61508

Datasheet as PDF in following languages:


Technical Data: FB4305C

Supply
Connectionbackplane bus
Rated voltage12 V DC , only in connection with the power supplies FB92**
Power consumption3 W
Internal bus
Connectionbackplane bus
Interfacemanufacturer specific bus to standard com unit/bus coupler
Output
Number of channels4
Connectionwire ends 1+ (white), 2- (brown), 3+ (green), 4- (yellow), 5+ (grey), 6- (pink)
Current4 ... 20 mA (0 ... 25 mA)
short-circuit protected
Load750 Ω max.
Line fault detectionmin. 1 mA
Response thresholdmin. 850 Ω
Watchdogoutput off 0.5 s after serious fault
Transfer characteristics
Deviation0.1 % of the input signal range at 20 В°C (68 В°F)
Refresh timeapprox. 58 ms (4 channels)
110 ms during HART
Indicators/settings
LED indicatorLED green: supply
LED red: line fault , communication error
Directive conformity
Electromagnetic compatibility
Directive 2004/108/ECEN 61326-1
Conformity
Electromagnetic compatibilityNE 21
Protection degreeIEC 60529
Ambient conditions
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Relative humidity95 % non-condensing
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 50 m/s2, number of shock directions 6, number of shocks per direction 100
Vibration resistancefrequency range 5 ... 500 Hz, amplitude 5 ... 13.2 Hz ± 1.5 mm, 13.2 ... 100 Hz 1g, sweep rate 1 octave/min, duration 10 sweeps 5 Hz - 100 Hz - 5 Hz
Damaging gasfor plugs: 21 days in 25 ppm SO2, at 25 В°C and 75 % rel. humidity, device G3
Mechanical specifications
Protection degreeIP20 (module) , a separate housing is required acc. to the system description
Connectionwire ends or shielded cable tail
wiring connection: separately covered Ex e terminals required
Massapprox. 750 g
Dimensions57 x 107 x 132 mm (2.2 x 4.2 x 5.2 in)
Data for application in connection with Ex-areas
EC-Type Examination CertificatePTB 97 ATEX 1074 U , PTB 97 ATEX 1075 (system) , for additional certificates see www.pepperl-fuchs.com
Group, category, type of protectionEx-Hexagon II 2 G Ex d IIC
Electrical isolation
Output/power supply, internal bussafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 94/9/ECEN 60079-0 , EN 60079-1
International approvals
IECEx approvalpending