3VL7

3VL7112-2KE30-0AA0 MOLDED CASE SWITCH, THERMAL MAGNETIC, MOLDED CASE; NG FRAME; 240/480/600 VAC AT 50/60 HZ, 250/500 VDC (UL); 240/415/690 VAC AT 50/60 HZ, 250 VDC (IEC); 1200 AMPERE AT 40 DEG C; 3 POLE _ Siemens
3VL7112-2KE30-0AA0 MOLDED CASE SWITCH, THERMAL MAGNETIC, MOLDED CASE; NG FRAME; 240/480/600 VAC AT 50/60 HZ, 250/500 VDC (UL); 240/415/690 VAC AT 50/60 HZ, 250 VDC (IEC); 1200 AMPERE AT 40 DEG C; 3 POLE _ Siemens
3VL7110-2GD30-0AA0 MOLDED CASE CIRCUIT BREAKER, SOLID STATE, MOLDED CASE; NG FRAME; 240/480/600 VAC AT 50/60 HZ, 250/500 VDC (UL); 240/415/690 VAC AT 50/60 HZ, 250 VDC (IEC); 1000 AMPERE AT 40 DEG C; 3 POLE _ Siemens
3VL7112-3GE30-0AA0 MOLDED CASE CIRCUIT BREAKER, SOLID STATE, MOLDED CASE; NG FRAME; 240/480/600 VAC AT 50/60 HZ, 250/500 VDC (UL); 240/415/690 VAC AT 50/60 HZ, 250 VDC (IEC); 1200 AMPERE AT 40 DEG C; 3 POLE _ Siemens
3VL71102GE300AA0 MOLDED CASE CIRCUIT BREAKER, SOLID STATE, MOLDED CASE; NG FRAME; 240/480/600 VAC AT 50/60 HZ, 250/500 VDC (UL); 240/415/690 VAC AT 50/60 HZ, 250 VDC (IEC); 1000 AMPERE AT 40 DEG C; 3 POLE _ Siemens
3VL7112-2GB30-0AA0 MOLDED CASE CIRCUIT BREAKER, SOLID STATE, MOLDED CASE; NG FRAME; 240/480/600 VAC AT 50/60 HZ, 250/500 VDC (UL); 240/415/690 VAC AT 50/60 HZ, 250 VDC (IEC); 1200 AMPERE AT 40 DEG C; 3 POLE _ Siemens
3VL7712-3NN46-0A.. . VL 1250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-3TN46-.... . VL 1250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED SIEMENS
3VL7712-3NH46-0A.. . VL 1250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-3TH46-.... . VL 1250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL7712-3NF46-0A.. . VL 1250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-3TF46-.... . VL 1250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL7712-3NB46-0A.. . VL 1250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-3TB46-.... . VL 1250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED SIEMENS
3VL7712-3MH36-0A.. . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-3SH36-.... . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT SIEMENS
3VL7712-3MG36-0A.. . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-3SG36-.... . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT SIEMENS
3VL7712-3ML36-0A.. . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-3SL36-.... . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT SIEMENS
3VL7712-3ME36-0A.. . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-3SE36-.... . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT SIEMENS
3VL7712-3MB36-0A.. . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-3SB36-.... . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT SIEMENS
3VL7712-3LF46-.... . VL 1250L .... ICU= 100KA, 415V AC 4-., PLANT PROTECTION .. ETU20, LSI IN= 1250A, RATED CURRENT IR= 500...1250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7712-3LE36-.... . VL 1250L .... ICU= 100KA, 415V AC 3-., PLANT PROTECTION .. ETU20, LSI IN= 1250A, RATED CURRENT IR= 500...1250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7712-3LB36-.... . VL 1250L .... ICU= 100KA, 415V AC 3-., PLANT PROTECTION .. ETU10, LI IN= 1250A, RATED CURRENT IR= 500...1250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7712-3LA46-.... . VL 1250L .... ICU= 100KA, 415V AC 4-., PLANT PROTECTION .. ETU10, LI IN= 1250A, RATED CURRENT IR= 500...1250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7712-3EE46-.... VL 1250L ICU=100KA/415 V AC 4-, IN=1250A, II=12000A, .. SIEMENS
3VL7712-3DE36-.... VL 1250L ICU=100KA/415 V AC 3-, IN=1250A, II=12000A, .. SIEMENS
3VL7712-3CM36-.... VL 1250L ICU=100KA/415 V AC 3-, , LCD ETU42, LSIG 3 /4 IN=1250A, IR=500-1250A, ISD=1,5 10XIR, I SIEMENS
3VL7712-3CL36-.... VL 1250L ICU=100KA/415 V AC 3-, , LCD ETU42, LSIG 3 /3 IN=1250A, IR=500-1250A, ISD=1,5 10XIR, I SIEMENS
3VL7712-3CJ46-.... VL 1250L ICU=100KA/415 V AC 4-, , LCD ETU40, LI/LS/LSI IN=1250A, IR=500-1250A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL7712-3CH36-.... VL 1250L ICU=100KA/415 V AC 3-, , LCD ETU40, LI/LS/LSI IN=1250A, IR=500-1250A, ISD=1,5 10XIR, II=11XIN .. SIEMENS
3VL7712-3AA46-0AA0 . VL 1250L . ... ICU=100KA / 415 V AC 4 . IN= < 1250A, RATED CURRENT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-3AA36-0AA0 . VL 1250L . ... ICU=100KA / 415 V AC 3 . IN= < 1250A, RATED CURRENT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-2TN46-.... . VL 1250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED SIEMENS
3VL7712-2NH46-0A.. . VL 1250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-2NF46-0A.. . VL 1250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-2ME36-0A.. . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-2MB36-0A.. . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-2LF46-.... . VL 1250H ... ICU= 70KA, 415V AC 4-., PLANT PROTECTION .. ETU20, LSI IN= 1250A, RATED CURRENT IR= 500...1250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7712-2LE36-.... . VL 1250H ... ICU= 70KA, 415V AC 3-., PLANT PROTECTION .. ETU20, LSI IN= 1250A, RATED CURRENT IR= 500...1250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7712-2LB36-.... . VL 1250H ... ICU= 70KA, 415V AC 3-., PLANT PROTECTION .. ETU10, LI IN= 1250A, RATED CURRENT IR= 500...1250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7712-2LA46-.... . VL 1250H ... ICU= 70KA, 415V AC 4-., PLANT PROTECTION .. ETU10, LI IN= 1250A, RATED CURRENT IR= 500...1250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7712-2EE46-.... VL 1250 H ICU=70KA/415 V AC 4-, IN=1250A, II=12000A, .. SIEMENS
3VL7712-1NN46-0A.. . VL 1250N . .. ICU=50KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-1NH46-0A.. . VL 1250N . .. ICU=50KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-1NF46-0A.. . VL 1250N . .. ICU=50KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-1NB46-0A.. . VL 1250N . .. ICU=50KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-1MH36-0A.. . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-1MG36-0A.. . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-1ML36-0A.. . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-1ME36-0A.. . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-1SE36-.... . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT SIEMENS
3VL7712-1MB36-0A.. . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-1SB36-.... . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT SIEMENS
3VL7712-1LF46-.... . VL 1250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION .. ETU20, LSI IN= 1250A, RATED CURRENT IR= 500...1250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7712-1LE36-.... . VL 1250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION .. ETU20, LSI IN= 1250A, RATED CURRENT IR= 500...1250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7712-1LB36-.... . VL 1250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION .. ETU10, LI IN= 1250A, RATED CURRENT IR= 500...1250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7712-1LA46-.... . VL 1250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION .. ETU10, LI IN= 1250A, RATED CURRENT IR= 500...1250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7712-1EE46-.... VL 1250N ICU=50KA/415 V AC 4-, IN=1250A, II=12000A, .. SIEMENS
3VL7712-1DE36-.... VL 1250N ICU=50KA/415 V AC 3-, IN=1250A, II=12000A, .. SIEMENS
3VL7712-1CN46-.... VL 160 H ICU=70KA/415 V AC 4-, , LCD ETU42, LSIG IN=1250A, IR=500-1250A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL7712-1CM36-.... VL 1250N ICU=50KA/415 V AC 3-, , LCD ETU42, LSIG 3 /4 IN=1250A, IR=500-1250A, ISD=1,5 10XIR, II=1 SIEMENS
3VL7712-1CL36-.... VL 1250N ICU=50KA/415 V AC 3-, , LCD ETU42, LSIG 3 /3 IN=1250A, IR=500-1250A, ISD=1,5 10XIR, II=1 SIEMENS
3VL7712-1CJ46-.... VL 1250N ICU=50KA/415 V AC 4-, , LCD ETU40, LI/LS/LSI IN=1250A, IR=500-1250A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL7712-1CH36-.... VL 1250N ICU=50KA/415 V AC 3-, , LCD ETU40, LI/LS/LSI IN=1250A, IR=500-1250A, ISD=1,5 10XIR, II=11XIN .. SIEMENS
3VL7712-1AA46-0AA0 . VL 1250N . .. ICU=50KA / 415 V AC 4 . IN= < 1250A, RATED CURRENT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-1AA36-0AA0 . VL 1250N . .. ICU=50KA / 415 V AC 3 . IN= < 1250A, RATED CURRENT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-3NN46-0A.. . VL 1250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-3TN46-.... . VL 1250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N PROTECTED SIEMENS
3VL7710-3NH46-0A.. . VL 1250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-3TH46-.... . VL 1250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL7710-3NF46-0A.. . VL 1250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-3TF46-.... . VL 1250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL7710-3MH36-0A.. . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-3SH36-.... . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL7710-3MG36-0A.. . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-3SG36-.... . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL7710-3SL36-.... . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT SIEMENS
3VL7710-3ME36-0A.. . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-3SE36-.... . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL7710-3MB36-0A.. . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-3SB36-.... . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT SIEMENS
3VL7710-3LF46-.... . VL 1250L . ... ICU= 100KA, 415V AC 4-., PLANT PROTECTION .. ETU20, LSI IN= 1000A, RATED CURRENT IR= 400...1000A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7710-3LE36-.... . VL 1250L . ... ICU= 100KA, 415V AC 3-., PLANT PROTECTION .. ETU20, LSI IN= 1000A, RATED CURRENT IR= 400...1000A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7710-3LB36-.... . VL 1250L . ... ICU= 100KA, 415V AC 3-., PLANT PROTECTION .. ETU10, LI IN= 1000A, RATED CURRENT IR= 400...1000A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7710-3LA46-.... . VL 1250L . ... ICU= 100KA, 415V AC 4-., PLANT PROTECTION .. ETU10, LI IN= 1000A, RATED CURRENT IR= 400...1000A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7710-3CM36-.... VL 1250L ICU=100KA/415 V AC 3-, , LCD ETU42, LSIG 3 /4 IN=1000A, IR=400-1000A, ISD=1,5 10XIR, I SIEMENS
3VL7710-3CL36-.... VL 1250L ICU=100KA/415 V AC 3-, , LCD ETU42, LSIG 3 /3 IN=1000A, IR=400-1000A, ISD=1,5 10XIR, I SIEMENS
3VL7710-3CJ46-.... VL 1250L ICU=100KA/415 V AC 4-, , LCD ETU40, LI/LS/LSI IN=1000A, IR=400-1000A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL7710-3CH36-.... VL 1250L ICU=100KA/415 V AC 3-, , LCD ETU40, LI/LS/LSI IN=1000A, IR=400-1000A, ISD=1,5 10XIR, II=11XIN .. SIEMENS
3VL7710-2NN46-0A.. . VL 1250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-2TN46-.... . VL 1250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N PROTECTED SIEMENS
3VL7710-2NH46-0A.. . VL 1250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-2TH46-.... . VL 1250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL7710-2NF46-0A.. . VL 1250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-2TF46-.... . VL 1250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL7710-2NB46-0A.. . VL 1250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-2TB46-.... . VL 1250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N PROTECTED SIEMENS
3VL7710-2MH36-0A.. . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-2SH36-.... . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL7710-2MG36-0A.. . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-2SG36-.... . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL7710-2ML36-0A.. . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-2SL36-.... . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT SIEMENS
3VL7710-2ME36-0A.. . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-2CL36-.... VL 1250 H ICU=70KA/415 V AC 3-, , LCD ETU42, LSIG 3 /3 IN=1000A, IR=400-1000A, ISD=1,5 10XIR, II=11XI SIEMENS
3VL7710-2CJ46-.... VL 1250 H ICU=70KA/415 V AC 4-, , LCD ETU40, LI/LS/LSI IN=1000A, IR=400-1000A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL7710-2CH36-.... VL 1250 H ICU=70KA/415 V AC 3-, , LCD ETU40, LI/LS/LSI IN=1000A, IR=400-1000A, ISD=1,5 10XIR, II=11XIN .. SIEMENS
3VL7710-1NN46-0A.. . VL 1250N . .. ICU=50KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-1TN46-.... . VL 1250N . .. ICU=50KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N PROTECTED SIEMENS
3VL7710-1NH46-0A.. . VL 1250N . .. ICU=50KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-1TH46-.... . VL 1250N . .. ICU=50KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL7710-1MH36-0A.. . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-1SH36-.... . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL7710-1MG36-0A.. . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-1SG36-.... . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL7710-1ML36-0A.. . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-1SL36-.... . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT SIEMENS
3VL7710-1ME36-0A.. . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-1SE36-.... . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL7710-1MB36-0A.. . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-1SB36-.... . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT SIEMENS
3VL7710-1LF46-.... . VL 1250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION .. ETU20, LSI IN= 1000A, RATED CURRENT IR= 400...1000A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7710-1LE36-.... . VL 1250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION .. ETU20, LSI IN= 1000A, RATED CURRENT IR= 400...1000A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7710-1LB36-.... . VL 1250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION .. ETU10, LI IN= 1000A, RATED CURRENT IR= 400...1000A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7710-1LA46-.... . VL 1250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION .. ETU10, LI IN= 1000A, RATED CURRENT IR= 400...1000A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7710-1CM36-.... VL 1250N ICU=50KA/415 V AC 3-, , LCD ETU42, LSIG 3 /4 IN=1000A, IR=400-1000A, ISD=1,5 10XIR, II=1 SIEMENS
3VL7710-1CL36-.... VL 1250N ICU=50KA/415 V AC 3-, , LCD ETU42, LSIG 3 /3 IN=1000A, IR=400-1000A, ISD=1,5 10XIR, II=1 SIEMENS
3VL7710-1CJ46-.... VL 1250N ICU=50KA/415 V AC 4-, , LCD ETU40, LI/LS/LSI IN=1000A, IR=400-1000A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL7710-1CH36-.... VL 1250N ICU=50KA/415 V AC 3-, , LCD ETU40, LI/LS/LSI IN=1000A, IR=400-1000A, ISD=1,5 10XIR, II=11XIN .. SIEMENS
3VL7190-3KN30-.... . VL 1200 UL; NG (CAT NO. LNX3B900) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 900A, RATED CURRENT II= 6000...10000A SHORT-CIRCUIT PROTECTION IR= 900A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7190-2KN30-.... . VL 1200 UL; NG (CAT NO. HNX3B900) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 900A, RATED CURRENT II= 6000...10000A SHORT-CIRCUIT PROTECTION IR= 900A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7190-1KN30-.... . VL 1200 UL; NG (CAT NO. NNX3B900) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 900A, RATED CURRENT II= 6000...10000A SHORT-CIRCUIT PROTECTION IR= 900A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-3KN30-.... . VL 1200 UL; NG (CAT NO. LNX3B800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 800A, RATED CURRENT II= 4000...8000A SHORT-CIRCUIT PROTECTION IR= 800A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-3JM30-.... . VL 1200 UL; NG (CAT NO. LNX3E800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 800A, RATED CURRENT ISD=1.25 TO 10 X IR, II=8 X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-3JH30-.... . VL 1200 UL; NG (CAT NO. LNX3D800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 800A, RATED CURRENT ISD=1.25 TO 10 X IR, II=8X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-3GH30-.... . VL 1200 UL; NG (CAT NO. LNX3U800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 800A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-3GE30-.... . VL 1200 UL; NG (CAT NO. LNX3P800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 800A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-3GD30-.... . VL 1200 UL; NG (CAT NO. LNX3X800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 800A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-3GB30-.... . VL 1200 UL; NG (CAT NO. LNX3N800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 800A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-2KN30-.... . VL 1200 UL; NG (CAT NO. HNX3B800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 800A, RATED CURRENT II= 4000...8000A SHORT-CIRCUIT PROTECTION IR= 800A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-2JM30-.... . VL 1200 UL; NG (CAT NO. HNX3E800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 800A, RATED CURRENT ISD=1.25 TO 10 X IR, II=8 X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-2JH30-.... . VL 1200 UL; NG (CAT NO. HNX3D800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 800A, RATED CURRENT ISD=1.25 TO 10 X IR, II=8X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-2GH30-.... . VL 1200 UL; NG (CAT NO. HNX3U800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 800A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-2GE30-.... . VL 1200 UL; NG (CAT NO. HNX3P800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 800A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-2GD30-.... . VL 1200 UL; NG (CAT NO. HNX3X800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 800A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-2GB30-.... . VL 1200 UL; NG (CAT NO. NNX3N800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 800A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-1KN30-.... . VL 1200 UL; NG (CAT NO. NNX3B800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 800A, RATED CURRENT II= 4000...8000A SHORT-CIRCUIT PROTECTION IR= 800A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-1JM30-.... . VL 1200 UL; NG (CAT NO. NNX3E800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 800A, RATED CURRENT ISD=1.25 TO 10 X IR, II=8 X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-1JH30-.... . VL 1200 UL; NG (CAT NO. NNX3D800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 800A, RATED CURRENT ISD=1.25 TO 10 X IR, II=8X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-1GH30-.... . VL 1200 UL; NG (CAT NO. NNX3U800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 800A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-1GE30-.... . VL 1200 UL; NG (CAT NO. NNX3P800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= 800A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-1GD30-.... . VL 1200 UL; NG (CAT NO. NNX3X800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 800A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7180-1GB30-.... . VL 1200 UL; NG (CAT NO. LNX3N800) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 800A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-6KN30-0AA0 BREAKER VL 3P 1200A 480V 65KA FX TM 100 CAT NUMBER HNY3B120 SIEMENS
3VL7112-5KN30-0AA0 BREAKER VL 3P 1200A 480V 35KA FX TM 100 CAT NUMBER NNY3B120 SIEMENS
3VL7112-3KN30-.... . VL 1200 UL; NG (CAT NO. LNX3B120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 1200A, RATED CURRENT II= 7000...12000A SHORT-CIRCUIT PROTECTION IR= 1200A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-3KE30-.... . VL 1200 UL; NG (CAT NO. LNS3S120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE SWITCH) MAGNETIC TU= 40 DEGR. CELSIUS IN= < 1200A, RATED CURRENT II= 12000A SHORT-CIRCUIT PROTECTION ISOLATING . W/O CONNECTION SIEMENS
3VL7112-3JM30-.... . VL 1200 UL; NG (CAT NO. LNX3E120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 1200A, RATED CURRENT ISD=1.25 TO 10 X IR, II=10X IN SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-3JH30-.... . VL 1200 UL; NG (CAT NO. LNX3D120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 1200A, RATED CURRENT ISD=1.25 TO 10 X IR, II=10X IN SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-3GH30-.... . VL 1200 UL; NG (CAT NO. LNX3U120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 1200A, RATED CURRENT ISD=1.5 TO 10 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-3GE30-.... . VL 1200 UL; NG (CAT NO. LNX3P120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 1200A, RATED CURRENT ISD=1.5 TO 10 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-3GD30-.... . VL 1200 UL; NG (CAT NO. LNX3X120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 1200A, RATED CURRENT II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-3GB30-.... . VL 1200 UL; NG (CAT NO. LNX3N120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 1200A, RATED CURRENT II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-2KN30-.... . VL 1200 UL; NG (CAT NO. HNX3B120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 1200A, RATED CURRENT II= 7000...12000A SHORT-CIRCUIT PROTECTION IR= 1200A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-2KK30-.... . VL 1200 UL; NG (CAT NO. HNM3M120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOTOR STARTER PROTECTOR) MAGNETIC TU= 40 DEGR. CELSIUS IN= < 1200A, RATED CURRENT II= 5000...10000A SHORT-CIRCUIT PROTECTION STARTER COMBINATION W/O CONNECTION SIEMENS
3VL7112-2KE30-.... . VL 1200 UL; NG (CAT NO. HNS3S120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE SWITCH) MAGNETIC TU= 40 DEGR. CELSIUS IN= < 1200A, RATED CURRENT II= 12000A SHORT-CIRCUIT PROTECTION ISOLATING . W/O CONNECTION SIEMENS
3VL7112-2JM30-.... . VL 1200 UL; NG (CAT NO. HNX3E120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 1200A, RATED CURRENT ISD=1.25 TO 10 X IR, II=10X IN SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-2JH30-.... . VL 1200 UL; NG (CAT NO. HNX3D120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 1200A, RATED CURRENT ISD=1.25 TO 10 X IR, II=10X IN SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-2GH30-.... . VL 1200 UL; NG (CAT NO. HNX3U120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 1200A, RATED CURRENT ISD=1.5 TO 10 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-2GE30-.... . VL 1200 UL; NG (CAT NO. HNX3P120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 1200A, RATED CURRENT ISD=1.5 TO 10 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-2GD30-.... . VL 1200 UL; NG (CAT NO. HNX3X120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 1200A, RATED CURRENT II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-2GB30-.... . VL 1200 UL; NG (CAT NO. HNX3N120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 1200A, RATED CURRENT II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-1GE30-.... . VL 1200 UL; NG (CAT NO. NNX3P120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 1200A, RATED CURRENT ISD=1.5 TO 10 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-1GD30-.... . VL 1200 UL; NG (CAT NO. NNX3X120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 1200A, RATED CURRENT II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-1GB30-.... . VL 1200 UL; NG (CAT NO. NNX3N120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 1200A, RATED CURRENT II= 1.25 TO 10 X IN, SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-3KN30-.... . VL 1200 UL; NG (CAT NO. HNX3B100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 1000A, RATED CURRENT II= 6000...10000A SHORT-CIRCUIT PROTECTION IR= 1000A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7712-2DE36-.... VL 1250 H ICU=70KA/415 V AC 3-, IN=1250A, II=12000A, .. SIEMENS
3VL7712-3CN46-.... VL 160L ICU=100KA/415 V AC 4-, , LCD ETU42, LSIG IN=1250A, IR=500-1250A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL7712-2CM36-.... VL 1250 H ICU=70KA/415 V AC 3-, , LCD ETU42, LSIG 3 /4 IN=1250A, IR=500-1250A, ISD=1,5 10XIR, II=11XI SIEMENS
3VL7712-2CL36-.... VL 1250 H ICU=70KA/415 V AC 3-, , LCD ETU42, LSIG 3 /3 IN=1250A, IR=500-1250A, ISD=1,5 10XIR, II=11XI SIEMENS
3VL7712-2CJ46-.... VL 1250 H ICU=70KA/415 V AC 4-, , LCD ETU40, LI/LS/LSI IN=1250A, IR=500-1250A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL7712-2CH36-.... VL 1250 H ICU=70KA/415 V AC 3-, , LCD ETU40, LI/LS/LSI IN=1250A, IR=500-1250A, ISD=1,5 10XIR, II=11XIN .. SIEMENS
3VL7712-2AA46-0AA0 . VL 1250H ... ICU=70KA / 415 V AC 4 . IN= < 1250A, RATED CURRENT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-2AA36-0AA0 . VL 1250H ... ICU=70KA / 415 V AC 3 . IN= < 1250A, RATED CURRENT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-1NN46-.... . VL 1250N . .. ICU=50KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED SIEMENS
3VL7712-1NH46-.... . VL 1250N . .. ICU=50KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL7712-1NF46-.... . VL 1250N . .. ICU=50KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL7712-1NB46-.... . VL 1250N . .. ICU=50KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED SIEMENS
3VL7712-1MH36-.... . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT SIEMENS
3VL7712-1MG36-.... . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT SIEMENS
3VL7712-1ML36-.... . VL 1250N . .. ICU=50KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT SIEMENS
3VL7710-2SE36-.... . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL7710-2MB36-0A.. . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-2SB36-.... . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT SIEMENS
3VL7710-2LF46-.... . VL 1250H ... ICU= 70KA, 415V AC 4-., PLANT PROTECTION .. ETU20, LSI IN= 1000A, RATED CURRENT IR= 400...1000A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7710-2LE36-.... . VL 1250H ... ICU= 70KA, 415V AC 3-., PLANT PROTECTION .. ETU20, LSI IN= 1000A, RATED CURRENT IR= 400...1000A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7710-2LB36-.... . VL 1250H ... ICU= 70KA, 415V AC 3-., PLANT PROTECTION .. ETU10, LI IN= 1000A, RATED CURRENT IR= 400...1000A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7710-2LA46-.... . VL 1250H ... ICU= 70KA, 415V AC 4-., PLANT PROTECTION .. ETU10, LI IN= 1000A, RATED CURRENT IR= 400...1000A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL7710-3CN46-.... VL 160L ICU=100KA/415 V AC 4-, , LCD ETU42, LSIG IN=1000A, IR=400-1000A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL7710-2CM36-.... VL 1250 H ICU=70KA/415 V AC 3-, , LCD ETU42, LSIG 3 /4 IN=1000A, IR=400-1000A, ISD=1,5 10XIR, II=11XI SIEMENS
3VL7110-3JM30-.... . VL 1200 UL; NG (CAT NO. LNX3E100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 1000A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-3JH30-.... . VL 1200 UL; NG (CAT NO. LNX3D100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 1000A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-2KN30-.... . VL 1200 UL; NG (CAT NO. HNX3B100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 1000A, RATED CURRENT II= 6000...10000A SHORT-CIRCUIT PROTECTION IR= 1000A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-2JM30-.... . VL 1200 UL; NG (CAT NO. HNX3E100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 1000A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-2JH30-.... . VL 1200 UL; NG (CAT NO. HNX3D100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 1000A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-2GH30-.... . VL 1200 UL; NG (CAT NO. HNX3U100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 1000A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-2GE30-.... . VL 1200 UL; NG (CAT NO. HNX3P100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 1000A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-2GD30-.... . VL 1200 UL; NG (CAT NO. HNX3X100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 1000A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-2GB30-.... . VL 1200 UL; NG (CAT NO. HNX3N100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 1000A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-1KN30-.... . VL 1200 UL; NG (CAT NO. NNX3B100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 1000A, RATED CURRENT II= 6000...10000A SHORT-CIRCUIT PROTECTION IR= 1000A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-1JM30-.... . VL 1200 UL; NG (CAT NO. NNX3E100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 1000A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-1JH30-.... . VL 1200 UL; NG (CAT NO. NNX3D100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 1000A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-1GH30-.... . VL 1200 UL; NG (CAT NO. NNX3U100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 1000A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-1GE30-.... . VL 1200 UL; NG (CAT NO. NNX3P100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 1000A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-1GD30-.... . VL 1200 UL; NG (CAT NO. NNX3X100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 1000A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-1GB30-.... . VL 1200 UL; NG (CAT NO. NNX3N100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 1000A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7712-2NB46-0A.. . VL 1250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-2MF36-0A.. . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-2MH36-0A.. . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-2MG36-0A.. . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-3NB46-0A.. . VL 1250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-3TB46-.... . VL 1250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N PROTECTED SIEMENS
3VL7710-3MF36-0A.. . VL 1250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-1NF46-0A.. . VL 1250N . .. ICU=50KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-1TF46-.... . VL 1250N . .. ICU=50KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL7710-1NB46-0A.. . VL 1250N . .. ICU=50KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7710-1TB46-.... . VL 1250N . .. ICU=50KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N PROTECTED SIEMENS
3VL7112-1KN30-.... . VL 1200 UL; NG (CAT NO. NNX3B120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 1200A, RATED CURRENT II= 7000...12000A SHORT-CIRCUIT PROTECTION IR= 1200A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-1JM30-.... . VL 1200 UL; NG (CAT NO. NNX3E120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 1200A, RATED CURRENT ISD=1.25 TO 10 X IR, II=10X IN SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-1JH30-.... . VL 1200 UL; NG (CAT NO. NNX3D120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 1200A, RATED CURRENT ISD=1.25 TO 10 X IR, II=10X IN SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7112-1GH30-.... . VL 1200 UL; NG (CAT NO. NNX3U120) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 1200A, RATED CURRENT ISD=1.5 TO 10 X IR, II=10 X IN SHORT-CIRCUIT PROTECTION IR= 400-1200A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-3GH30-.... . VL 1200 UL; NG (CAT NO. LNX3U100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 1000A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-3GE30-.... . VL 1200 UL; NG (CAT NO. LNX3P100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 1000A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-3GD30-.... . VL 1200 UL; NG (CAT NO. LNX3X100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 1000A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7110-3GB30-.... . VL 1200 UL; NG (CAT NO. LNX3N100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 1000A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 400-1000A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL7712-2NF46-.... . VL 1250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL7712-2NB46-.... . VL 1250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED SIEMENS
3VL7712-2MH36-.... . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT SIEMENS
3VL7712-2MG36-.... . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT SIEMENS
3VL7712-2MF36-.... . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT SIEMENS
3VL7712-2ME36-.... . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT SIEMENS
3VL7712-2MB36-.... . VL 1250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT SIEMENS
3VL7712-2NN46-0A.. . VL 1250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL7712-2NH46-.... . VL 1250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL7012-3RA30-0AA0 BREAKER VL FRAME 1200A 3P 100KA CAT NMB. LNG3F120 FRAME 1200A 3P 100KA - 3VL70123RA300AA0 Siemens
3VL7012-2RA30-0AA0 BREAKER VL CAT NMB. HNG3F120 3P 1200A 480V 65KA FR - 3VL70122RA300AA0 Siemens
3VL7012-1RA30-0AA0 BREAKER VL 3P 800A 480V 35KA FR CAT NMB. NNG3F120 3P 800A 480V 35KA FR - 3VL70121RA300AA0 Siemens

1 - 251 251